In today’s construction landscape, every moment counts. Our “Monolithic Dynamic Load Return to Service System” offers rapid, vibration-controlled repairs for dynamic load-induced foundation challenges, all while harnessing the strength of DP Epoxy Grout – Standard, HP (High Flow), or PG (Pump Grade) – to minimize disruptions and maintain peak productivity in your operations.

Download the PDF

PRODUCT

COMPRESSIVE STRENGTH
@ 70°F (21°C)

WORKING TIME
@ 70°F (21°C)

MIN DEPTH
OF POUR

MAX
DEPTH OF POUR/
VOLUME

ASTM C 579 B

RETURN TO SERVICE TIMEFRAME

XP 230 Epoxy Grout

4,000 psi
(28 MPa)
5 hours

45 mins.

2”
(51 mm)

18” (457 mm)
or

volumes up to 80 ft³ (2.2 m³)

5 Hrs

XP 230 Epoxy Grout

15,000 psi (103 MPa)
@ 70°F (21°C),
19,000 psi (131 MPa)
@ 90°F (32°C)

12 hours

45 mins.

2”
(51 mm)

18” (457 mm)
or

volumes up to 80 ft³ (2.2 m³)

12 Hrs

DP Epoxy Grout PG

9,000 psi
(62 MPa)
24 hours

75 mins.

½”
(13 mm)

6”
(152 mm)
or
volumes up to

50 ft³ (1.4 m³)

24 Hrs

DP Epoxy Grout High Flow

9,000 psi
(62 MPa)
24 hours

60 mins.

½”
(13 mm)

18”
(457 mm)

or
volumes up to
100 ft³ (2.8 m³)

24 Hrs

DP Epoxy Grout - Standard

11,000 psi
(76 MPa)
24 hours

90 mins.

½”
(13 mm)

18”
(457 mm)

or
volumes up to
100 ft³ (2.8 m³)

24 Hrs